Cassette air conditioners with universal outdoor units FORT series
Cassette air conditioners FORT series are light commercial eqipment with universal outdoor units. That series has a wide range of applications: offices, restaurants, conference rooms, shopping centers, hotels.
Complect includes panel with circular air flow.
Due to the circular air flow panel, air flows out of the unit in all directions.
FORT cassette air conditioners provide high quality air supply to all corners of the room and prevent air stagnation in the area.
All FORT cassette indoor units have a built-in drainage pump (condensate lift up to a height of 750 mm). It allows installation in places where it is impossible to provide a natural slope of the drainage pipeline.
Technical parameters
Model | complete set | RU1NC18ABE | RU0NC24ABE | RU0NC36ABD | RU0NC48ABD | RU0NC60ABD | |
---|---|---|---|---|---|---|---|
Capacity | cooling | kW | 5.28 | 7.046 | 10.548 | 14.068 | 16.114 |
heating | 5.576 | 7.612 | 11.124 | 15.242 | 17.864 | ||
Power supply | ph/V/Hz | 1/~(220±10%)/50 | 1/~(220±10%)/50 | 3/~(380-415)/50 | 3/~(380-415)/50 | 3/~(380-415)/50 | |
Rated power input | cooling | kW | 1.92 | 2.6 | 3.6 | 5.19 | 6.27 |
heating | 1.7 | 2.2 | 3.6 | 4.763 | 5.8 | ||
Operating current | cooling | A | 8.5 | 11.3 | 6.5 | 9.2 | 11.0 |
heating | 7.5 | 9.6 | 6.5 | 8.6 | 10.2 | ||
SEER/SCOP | 2.75/3.28 | 2.71/3.46 | 2.93/3.09 | 2.71/3.20 | 2.57/3.08 | ||
Energy class | D/C | D/B | C/D | D/D | E/D | ||
Air flow (max.) | м3/h | 730/570/470 | 1 300/1 000/820 | 1 960/1 660/1 400 | 1 916/1 780/1 620 | 2 000/1 920/1 730 | |
Noise level | indoor unit | dB(A) | 38/42/45 | 37/40/45 | 45/48/52 | 50/52/54 | 48/51/54 |
outdoor unit | 58.5 | 60 | 62.5 | 62 | 61.5 | ||
Refrigerant type | R410А | R410А | R410А | R410А | R410А | ||
Refrigerant charge* | kg | 1.3 | 2.0 | 2.85 | 3.3 | 3.3 | |
Parameters of refrigerant pipes | pipe diameter | liq. | 1/4'' | 3/8'' | 3/8'' | 3/8'' | 3/8'' |
gas | 1/2'' | 5/8'' | 3/4'' | 3/4'' | 3/4'' | ||
length (max) | м | 25 | 25 | 30 | 50 | 50 | |
height difference (max) | 15 | 15 | 20 | 30 | 30 | ||
Drain pipe (outside diameter) | mm | ø25 | ø25 | ø25 | ø25 | ø25 | |
Air switch** | nominal current | A | 20 | 32 | 25 | 32 | 32 |
Power cable (to IDU) | n×мм² | 3×2.5 | 3×2.5 | - | 5×2.5 | 5×2.5 | |
Power cable (to ODU) | - | - | 5×2.5 | - | - | ||
Interblock cable | 3×2.5+2×1.0+2×0.75 | 3×2.5+3×1.0+2×0.2 | 3×1.5+3×1.0 | 5×2.5+3×1.0 | 5×2.5+3×1.0 | ||
Dimensions (width × height × depth) |
indoor unit | mm | 570×260×570 | 830×205×830 | 830×245×830 | 830×245×830 | 830×287×830 |
panel | 647×50×647 | 950×55×950 | 950×55×950 | 950×55×950 | 950×55×950 | ||
outdoor unit | 805×554×330 | 890×673×342 | 946×810×410 | 900×1 170×350 | 900×1 170×350 | ||
Package dimensions (width × height × depth) |
indoor unit | mm | 655×290×655 | 910×250×910 | 910×250×910 | 910×250×910 | 910×330×910 |
panel | 715×123×715 | 1 035×90×1 035 | 1 035×90×1 035 | 1 035×90×1 035 | 1 035×90×1 035 | ||
outdoor unit | 915×615×370 | 995×740×398 | 1 090×875×500 | 1 032×1 307×443 | 1 032×1 307×443 | ||
ODU installation dimensions | mm | 511×317 | 663×348 | 673×403 | 590×378 | 590×378 | |
Weight (net / gross) | indoor unit | kg | 16.4/19.4 | 22.2/26.2 | 26.1/30.0 | 28.3/32.3 | 30.5/34.5 |
panel | 2.5/4.5 | 6/9 | 6/9 | 6/9 | 6/9 | ||
outdoor unit | 37.8/40.4 | 52.9/55.9 | 73.0/77.5 | 98.6/109.3 | 99.7/111.2 |
* The amount of freon is indicated for the pipe length of no more than 5 m. With an increase of the pipe length, it is necessary to charge the additional refrigerant at the rate of 15 g per 1 m for the 1/4″liquid pipe and 30 g per 1 m for the 3/8″liquid pipe.
** Cut-off current is not less than 7 In (In - rated current), leakage current is not more than 30mA, shutdown characteristic is «C». It is allowed to install the circuit breaker and RCD with the same capacity in series.
The table shows data for temperature conditions in accordance with ISO 5151-94:
- cooling mode inside 27 °C (DB)/19 °C (WB), outside 35 °C (DB)/24 °C (WB)
- heating mode inside 20 °C (DB)/15 °C (WB), outside 7 °C (DB)/6°C (WB)