Fresh III Inverter - RS2DF07BE
Inverter split systems ROVER become more efficient. Split-systems Fresh III Inverter series have energy class A ++ (SEER up to 7.4). Fresh III Inverter has an increased length of freon line and height difference сompared with models of previous years. The noise level has become lower.
Split-system Fresh III Inverter retains the laconic design of the Fresh II series: white glossy plastic and a matte functional display panel. Fresh III Inverter air conditioners are characterized by a wide choice of installation location, ease of installation, stable and durable service. This is achieved by improved characteristics of the freon line, the possibility of condensate drainage on the right or left side, as well as high-quality components.
Flexible control, advanced functionality and the ability to work at low temperatures allows you to continuously provide ideal conditions for a comfortable stay in the room.
Delivery set
- Autorestart
- Quite mode
- Turbo mode
- Automatic work
- Warm start
- Timer setting
- Self diagnosis
- Volumetric air flow
- Digital display
- Intellectual defrosting
- Low temperature heating
- Low temperature cooling
- Energy saving
Technical parameters
Model | complete set | RS2DF07BE | |
---|---|---|---|
Capacity | cooling | kW | 2.20 (1.30~3.00) |
heating | 2.30 (1.35~3.30) | ||
Power supply | V/ph/Hz | 220/1/50 | |
Rated power input | cooling | kW | 0.69 (0.16~0.95) |
heating | 0.64 (0.27~0.88) | ||
Rated current | cooling | A | 2.97 (0.9~4.3) |
heating | 2.77 (1.6~3.9) | ||
SEER/SCOP | 7.9/4.2 | ||
Energy class | A++/A+ | ||
Air flow (max ->min) | м3/h | 450/300/230 | |
Noise level | indoor unit | dB(A) | 20/22/31/33 |
outdoor unit | 50 | ||
Refrigerant type | R410А | ||
Refrigerant charge | kg | 0.52 | |
Standard pipe length (no need additional refrigerant) | м | 3 | |
Additional amount of refrigerant per 1m of liquid pipe | g/м | 20 | |
Parameters of refrigerant pipes | pipe diameter | liq. | 1/4″ |
gas | 3/8″ | ||
length (max) | м | 20 | |
height difference (max) | 10 | ||
Power cable (to IDU) | n×мм² | 3×1.0 | |
Interblock cable | 4×1.0 | ||
Dimensions (width × height × depth) |
indoor unit | mm | 690×283×199 |
outdoor unit | 660×500×240 | ||
Package dimensions (width × height × depth) |
indoor unit | mm | 760×280×345 |
outdoor unit | 780×550×345 | ||
ODU installation dimensions | mm | 500×260 | |
Weight (net / gross) | indoor unit | kg | 7.7/8.7 |
outdoor unit | 23/26 |
The table shows data for temperature conditions in accordance with ISO 5151-94:
- cooling mode inside 27 °C (DB)/19 °C (WB), outside 35 °C (DB)/24 °C (WB)
- heating mode inside 20 °C (DB)/15 °C (WB), outside 7 °C (DB)/6°C (WB)