Cassette air conditioners FORT II Inverter series

FORT II Inverter is the latest generation cassette air conditioners with a DC–inverter compressor. They are installed behind the suspended ceiling of offices, restaurants, shopping malls, hotels.

A neat white decorative panel with a circular flow of a cassette air conditioner goes well with any stylistic design and provides a reliable air supply to all corners of the room, and a built-in drain pump allows you to install the unit even in places where it is impossible to ensure a downward slope of the drainage pipeline.

Inverter systems of the FORT II Inverter series are represented by models: 18,000 BTU/h (RU2DC18BE), 24,000 BTU/h (RU2DC24BE), 36,000 BTU/h (RU2DC36BE), 48,000 BTU/h (RU2DC48BE), 60,000 BTU/h (RU2DC60BE).

Technical parameters

Model complete set RU2DC18BE RU2DC24BE RU2DC36BE RU2DC48BE RU2DC60BE
Capacity cooling kW 5.28 (2.9~5.59) 7.04 (3.3~7.92) 10.56 (2.7~11.43) 14.07 (3.52~15.83) 16.13 (4.1~16.71)
heating 5.57 (2.37~6.1) 7.62 (2.81~8.94) 11.14 (2.79~12.31) 16.13 (4.1~17.3) 18.18 (4.4~19.94)
Power supply indoor unit ph/V/Hz 1/~(220±10%)/50 1/~(220±10%)/50 1/~(220±10%)/50 1/~(220±10%)/50 1/~(220±10%)/50
outdoor unit 1/~(220±10%)/50 1/~(220±10%)/50 3/~(380-415)/50 3/~(380-415)/50 3/~(380-415)/50
Rated power input cooling kW 1.633 (0.72~2.088) 2.191 (0.78~2.748) 3.755 (0.89~4.15) 4.383 (0.80~5.9) 5.022 (0.98~6.2)
heating 1.54 (0.7~1.93) 1.9 (0.61~2.7) 3.0 (0.78~4.0) 4.465 (0.90~5.5) 5.034 (1.02~6.7)
Operating current cooling A 7.2 (3.2~9.2) 11 (4.2~12) 6.5 (1.4~6.5) 8.1 (1.8~10.2) 8.6 (2.1~10.7)
heating 6.8 (3.1~8.5) 8.5 (3.6~12.1) 5.0 (1.3~6.4) 8.0 (1.9~9.5) 9.6 (2.1~10.7)
SEER/SCOP 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0
Energy class A++/A+ A++/A+ A++/A+ A+/A+ A+/A+
Air flow (max.) м3/h 680/584/479 1247/1118/992 1700/1530/1300 1900/1750/1600 2000/1850/1650
Noise level indoor unit dB(A) 40/35/33 45/42/40 47/45//42 50/47/44 51/49/45
outdoor unit 59 60 63 63.5 64
Refrigerant type R32 R32 R32 R32 R32
Refrigerant charge* kg 1.15 1.5 2.4 2.9 3.0
Parameters of refrigerant pipes pipe diameter liq. 1/4'' 3/8'' 3/8'' 3/8'' 3/8''
gas 1/2'' 5/8'' 5/8'' 5/8'' 5/8''
length (max) м 35 55 80 80 80
height difference (max) 25 30 35 35 35
Drain pipe (outside diameter) mm ø25 ø25 ø25 ø25 ø25
Air switch** nominal current A 25 25 25 32 32
Power cable (to IDU) n×мм² - - - - -
Interblock cable 4×1.0 4×1.5 4×1.5 4×1.5 4×1.5
Dimensions
(width × height × depth)
indoor unit mm 570×260×570 830×205×830 830×245×830 830×287×830 830×287×830
panel 647×50×647 950×75×950 950×75×950 950×75×950 950×75×950
outdoor unit 805×554×330 890×673×342 946×810×410 952×1333×415 952×1333×415
Package dimensions
(width × height × depth)
indoor unit mm 662×317×662 910×250×910 910×290×910 910×330×910 910×330×910
panel 715×123×715 1 035×90×1 035 1 035×90×1 035 1 035×90×1 035 1 035×90×1 035
outdoor unit 915×615×370 995×740×398 1 090×885×500 1 095×1 480×495 1 095×1 480×495
ODU installation dimensions mm 511×317 663×348 673×403 634×404 634×404
Weight (net / gross) indoor unit kg 16/20.6 21.6/25.4 27.2/31.2 29.3/33.5 29.3/33.5
panel 2.5/4.5 6/9 6/9 6/9 6/9
outdoor unit 32.5/35.2 43.9/46.9 80.5/85 103.7/118.3 107.0/121.2

 

* The amount of freon is indicated for the pipe length of no more than 5 m. With an increase of the pipe length, it is necessary to charge the additional refrigerant at the rate of 12 g per 1 m for the 1/4″liquid pipe and 20 g per 1 m for the 3/8″liquid pipe.

** Cut-off current is not less than 7 In (In - rated current), leakage current is not more than 30mA, shutdown characteristic is «C». It is allowed to install the circuit breaker and RCD with the same capacity in series.

The table shows data for temperature conditions in accordance with ISO 5151-94:
- cooling mode inside 27 °C (DB)/19 °C (WB), outside 35 °C (DB)/24 °C (WB)
- heating mode inside 20 °C (DB)/15 °C (WB), outside 7 °C (DB)/6°C (WB)